An examination of five theoretical foundations associated with localized thermosensory testing


Creative Commons License

Temel M., Johnson A. A., Havenith G., Arnold J. T., West A. M., Lloyd A. B.

European Journal of Applied Physiology, cilt.121, sa.7, ss.1943-1954, 2021 (SCI-Expanded) identifier identifier

  • Yayın Türü: Makale / Tam Makale
  • Cilt numarası: 121 Sayı: 7
  • Basım Tarihi: 2021
  • Doi Numarası: 10.1007/s00421-021-04670-z
  • Dergi Adı: European Journal of Applied Physiology
  • Derginin Tarandığı İndeksler: Science Citation Index Expanded (SCI-EXPANDED), Scopus, Academic Search Premier, Abstracts in Social Gerontology, BIOSIS, CAB Abstracts, CINAHL, EMBASE, MEDLINE, SportDiscus, Veterinary Science Database
  • Sayfa Sayıları: ss.1943-1954
  • Anahtar Kelimeler: Confidence, Experimental design, Thermal discomfort, Thermal sensation, Thermosensory
  • Abdullah Gül Üniversitesi Adresli: Hayır

Özet

Purpose: To assess five theoretical foundations underlying thermosensory testing using local thermal stimuli. Methods: Thermal sensation, discomfort and the confidence of thermal sensation scores were measured in 9 female and 8 male volunteers in response to 17 physical contact temperature stimuli, ranging between 18–42 °C. These were applied to their dorsal forearm and lateral torso, across two sessions. Results: Thermal sensation to physical temperature relationships followed a positive linear and sigmoidal fit at both forearm (r2 = 0.91/r2 = 0.91, respectively) and lateral torso (r2 = 0.90/ r2 = 0.91, respectively). Thermal discomfort to physical temperature relationships followed second and third-order fits at both forearm (r2 = 0.33/r2 = 0.34, respectively) and lateral torso (r2 = 0.38/r2 = 0.39, respectively) test sites. There were no sex-related or regional site differences in thermal sensation and discomfort across a wide range of physical contact temperatures. The median confidence of an individual’s thermal sensation rating was measured at 86%. Conclusion: The relation between thermal sensation and physical contact temperature was well described by both linear and sigmoidal models, i.e., the distance between the thermal sensation anchors is close to equal in terms of physical temperatures changes for the range studied. Participants rated similar thermal discomfort level in both cold and hot thermal stimuli for a given increase or decrease in physical contact temperature or thermal sensation. The confidence of thermal sensation rating did not depend on physical contact temperature.